• nybjtp

Wholesale price CJX2F-630 Series 3P 630A Magnetic Telemecanique AC Contactor for Soft Starter

Short Description:

Scope of application

CJX2F series AC contactor is mainly used for AC 50Hz or 60Hz(with special coil, can be used for 40-400Hz),with working voltage up to 660V and working current up to 800A.It is used for long distance connection and breaking current.lt is also suitable for frequent start and control of electric motor.It can be combined with auxiliary contact group,air delay head,mechanical interlock,and then form mechanical interlock contactor,star-delta starter and suitable thermal overload relay.An electromagnetic starter is designed to protect from possibility of operating an overload circuit.


Product Detail

Product Tags

Normal operating conditions and installation condition

  • Ambient air temperature: -5°C~+40°C, the average value should not exceed +35°C within 24 hours.
  • Elevation: No more than 2000m.
  • Atmospheric conditions: The relative humidity of atmosphere should not exceed 50% at +40°C; When temperature is relatively low, relative humidity can be higher. While Monthly maximum relative humidity could be not more than 90% and special measures should be taken due to occurrence of dew.
  • Class of pollution: Class 3.
  • Installation category: Class lll.
  • Assembling conditions: The inclination of the mounting surface and the vertical plane should not be more than ±5°.
  • Impact shock: The product should be installed and used in places where there is no significant shaking, impact and vibration.

 

Main technical data and performance

  • Main specification of contactor
  • By current level: 115A, 150A, 185A, 225A, 265A, 330A, 400A, 500A, 630A, 800A.
  • According to the rated control power supply voltage Us of the contactor coil, it is divided into: AC 50Hz or 60Hz, 110V, 127V, 220V, 380V; DC 48V, 110V, 220V.

 

Basic technical data of contactor (Table 1)

Model of
contactor
Conventional
heating
current(A)
Rated working
current(A)
Max power of
controlled 3-phase
cage motor(KW)
Operation
cycles
per hour
Electrical
lifetime
(10^4 times)
Mechanical
lifetime
(10^4 times)
Matching
fuse(SCPD)
AC-3 AC-4 AC-3 Times/h Model Rated
current
380V 690V 380V 690V AC-3
CJX2F-115(Z) 200 115 86 55 80 1200 120 1000 RT16-1 200
CJX2F-150(Z) 200 150 108 75 100 1200 120 1000 RT16-1 225
CJX2F-185(Z) 275 185 118 90 110 600 100 600 RT16-2 315
CJX2F-225(Z) 275 225 137 110 129 600 100 600 RT16-2 315
CJX2F-265(Z) 315 265 170 132 160 600 80 600 RT16-2 355
CJX2F-330(z) 380 330 235 160 220 600 80 600 RT16-3 450
CJX2F-400(Z) 450 400 303 200 280 600 80 600 RT16-3 460
CJX2F-500 630 500 353 250 335 600 80 600 RT16-4 750
CJX2F-630 800 630 462 335 450 600 80 600 RT16-4 950
customize
CJX2F-800 800 800
(AC-3)
486
(AC-3)
450 475 600 60 300 N4 1000
CJX2F-800 800 630
(AC-4)
462
(AC-4)
335 450 600 60 300 N4 1000

 

Model and parameters of auxiliary contact group(Table 2)

Model of
auxiliary contact
Number of contact Rated insulation
Voltage (V)
Controlled capacity
Number of NO Number of NC
F4-02 0 2 660 AC-15 360VA
DC-13 33W
F4-11 1 1
F4-20 2 0
F4-40 4 0
F4-31 3 1
F4-22 2 2
F4-13 1 3
F4-04 0 4

 

Performance characteristic
·Pull-in voltage is 85%~110%,US
·The common contactor’s release voltage is 20%~75%Us,the energy-saving product’s release voltage is 10%~75%Us
·CJX2F contactor’s rated impulse withstand voltage is 8KV; Rated limit short circuit current is 50KA and the compatible type with SCPD is type-l.

 

 

Coil main specification code (Table 3,4)

Model CIX2F-115~265: 50Hz; CJX2F-330~800: 40~400Hz
110(AC) 127(AC) 220(AC) 380(AC) Power(VA)
Pick-up Holding
CJX2F-115,150 FF110 FF127 FF220 FF380 660 85.5
CJX2F-185,225 FG110 FG127 FG220 FG380 966 91.2
CJX2F-265 FH110 FH127 FH220 FH380 840 150
CJX2F-330 FL110 FL127 FL220 FL380 1500 34.2
CJX2F-400 FJ110 FJ127 FJ220 FJ380 1500 34.2
CJX2F-500 FK110 FK127 FK220 FK380 1500 34.2
CJX2F-630 FL110 FL127 FL220 FL380 1700 34.2
CJX2F-800 FM110 FM127 FM220 FM380 1700 34.2

Annotation: only coils of 3 poles and 4 poles products of CJX2F-330 and CJX2F-400 are compatible.

 

Model 48(DC) 110(DC) 220(DC) Power(VA)
Pick-up Holding
CJX2F-115Z,150Z FF 48 DC FF 110 DC FF 220 DC 1500 15
CJX2F-185Z,225Z FG 48 DC FG 110 DC FG 220 DC 1800 15
CJX2F-265Z FH 110 DC FH 220 DC 1500 15
CJX2F-330Z FI 110 DC FI 220 DC 1500 15
CJX2F-400Z FJ 110 DC FJ 220 DC 1800 15

 

 

The different betweent the CJX2 Series AC Contactor and CJX2F Series AC Contactor

 

AC contactors are important components in electrical systems and are used to control the flow of current to various devices. As far as AC contactors go, the CJX2 series and CJX2F series are two popular choices, but they differ greatly.

 

CJX2 series AC contactors are a widely used type known for their reliable performance and durability. It is designed for general purpose applications and is suitable for controlling circuits up to 660V AC. The CJX2 Series is popular in a wide range of industrial and commercial environments due to its compact size and ease of installation.

 

On the other hand, CJX2F series AC contactors are designed for frequent operation and are equipped with auxiliary contacts for signaling purposes. This series is ideally suited for applications requiring high frequency switching, such as conveyor systems, elevators and cranes. The CJX2F Series is designed to withstand the wear and tear of frequent use, making it the first choice for demanding environments.

 

One of the main differences between the two series is their structure. The CJX2F Series features a reinforced frame and enhanced contact materials, allowing it to handle the repetitive stress of frequent switching without compromising performance. In addition, the CJX2F series is equipped with a wider coil voltage range, providing greater flexibility for various electrical systems.

 

In terms of compatibility, the CJX2 series and CJX2F series are not interchangeable due to different designs and functions. It is important to select the correct series based on the specific requirements of the application to ensure optimal performance and longevity.

 

In summary, although both CJX2 series and CJX2F series AC contactors have the same basic purpose of controlling circuits, their unique features make them suitable for different applications. Understanding the differences between these series is critical to selecting the appropriate AC contactor for a specific electrical system, ultimately ensuring efficient and reliable operation.

 

02


  • Previous:
  • Next:

  • Write your message here and send it to us