| Type | NDR-480 | ||
| Output | DC Voltage/Rated Current | 24V/20A | 48V/10A |
| Current Range | 0 ~ 20A | 0 ~ 10A | |
| Rated Power | 480W | 480W | |
| Ripple&Noise | 150mVp-p | 150mVp-p | |
| DC Votage Area | 24 ~ 28V | 48 ~ 55V | |
| voltage accuracy | ± 1 .0% | ± 1 .0% | |
| linear adjustment rate | ± 0.5% | ± 0.5% | |
| Load Regulation | ± 1 .0% | ± 1 .0% | |
| Start and rise time | 1500ms, 100ms/230VAC 3000ms, 100ms/ 115VAC(FULL LOAD) | ||
| Storage time(Typ.) | 16ms/230VAC | ||
| Input | Voltage range | 180 ~ 264VAC | |
| Frequency Range | 47 ~ 63Hz | ||
| Efficiency (Typ.) | 88% | ||
| AC Current(Typ.) | 2.4A/230VAC | ||
| Surge Current(Typ.) | 35A/230VAC | ||
| Leakage Current | <2mA/ 240VAC | ||
| Protection characteristics | Excess Load | 105%~ 130% Rated output power | |
| Turn off the output voltage, and automatically recover after the load abnormal condition is removed. |
|||
| Over-volage | 29 ~ 33V | 56 ~ 65V | |
| Turn off the output and restore the normal output after the power is restarted. | |||
| Environmental science | Over-temperature | Turn off the output and restore the normal output after the power is restarted. | |
| Working temperature | -20~+70°C | ||
| Operating humidity | 20 ~ 95% RH, | ||
| Storage temperature/humidity | -40 ~ +85C, 10 ~ 95% RH | ||
| Temperature coefficient | ±0.03%/°C (0~50°C) | ||
| Vibration-proof | 10 ~ 500Hz, 2G 10Min/Cycle, X, Y, Z 60Min for each, Installation according to IEC60068-2-6 |
||
| Safety and electromagnetic compatibility |
Safety Specification | GB 4943.1-2011 | |
| Withstand Voltage | I/P-O/P:1.5KVAC I/P-FG:1.5VAC O/P-FG:0.5KVAC | ||
| Insulation resistance | IP-O/P, I/P-FG,O/P-FG:100M Ohms / 500VDC/25°C/70% RH | ||
| Electromagnetic compatibility emission | Conform to GB 17625.1-2012 | ||
| Electromagnetic compatibility immunity | Conform to GB/T 9254-2008 Grade A of the heavy industry standard | ||
| Size/Packages | 85.5*125.2*128.5mm (W*H*D)/ 1.5Kg; 8pcs/ 13Kg/0.9CUFT | ||
| Remarks | (1) Unless otherwise specified, All specification parameters are entered as 230VAC,Rated load test are making at 25°C enironment temperature. (2) Ripple and noise measurement methods: Use a12” twisted cable, At the same time, the terminal should be connected in parallel with 0.1uf and 47uf capacitors, Measurements are performed at 20MHZ bandwidth. (3) Accuracy: Includes setting error, Linear adjustment rate and load adjustment rate. (4) Installation distance: When the full power is permanently loaded, the recommended distance is 40mm from the top, 20mm from the bottom, and 5mm from the left and right sides. If the adjacent equipment is a heat source, the recommended space distance is 15mm. (5) When the altitude exceeds 2000m(6500ft),the ambient temperature of the fanless model decreases at a ratio of 3.5C/1000m, and that of the fanless model decreases at a ratio of 5C/1000m. |
||