The product realizes automatic detection and reclosing of circuit breakers.
If there is no fault, it will automatically reclose, and if there is a special fault, it will output a signal to the console.
I/O Control
When the CJ51RAi is in Auto mode, connect the device to the power supply, and use the I/O interface to remotely control the device to switch on and off.
1.Adjustable time and frequency.
2.Excessive auto-reclosing equipment will lock the product.
3.Modular assembly, more flexible installation can be adapted to more circuit breakers.
| Electrical Characteristics | |
| Standard | EN 50557 |
| Power Distribution System | TT – TN – S |
| Rated Voltage(Ue) | 230V AC (1) |
| Min Rated Voltage(Min Ue) | 85% Ue |
| Max Rated Voltage(Max Ue) | 110% Ue |
| Rated Insulation Voltage(Ui) | 500V |
| Diaelectric Strength | 2500V AC for 1 minute |
| Rated Withstand Voltage(Uimp) | 4kV |
| Over-voltage Category | III |
| Rated Frequency | 50 |
| Static Power | 1 |
| Power of remote control | 20 |
| Match electrical characteristics of circuit breaker | |
| MCB Type | 1P – 2P – 3P – 4P C – D |
| RCCB Type | AC – A – A[S] |
| RCBO Type | AC – A |
| Rated Current(In) | 25A – 40A – 63A – 80A – 100A |
| Rated Residual Current(I△n) | 30mA – 100mA – 300mA – 500mA |
| Protection Grade | IP20 (Outside the cabinet) – IP40 (Inside the cabinet) |
| Terminal Part of Breaker | Soft Cable:≤ 1x16mm² hard wire:≤ 1x25mm² |
| Mechanical Characteristics | |
| The Width of DIN Module | 2 |
| Reclosing times | Reclosing times [N]: 0~9 correspond to “0″, “1″, “2″, “3″, “4″, “5″, “6″, |
| “7″, “8″, “9″ times. | |
| Reclosing Time Interval | Reclosing time [T]: 0~9 correspond to “non-reclosing”, “10″, “20″, “30″, |
| “45″,”60″, “90″, “120″, “150″, “180″ seconds | |
| Max Operation Frequency | 30 |
| Maximum mechanical durability (total number of operations) | 10000 |
| Max. Auto Reclose Cycle | Reclosing times can be set |
| Enviroment Characterisics | |
| Pollution Grade | 2 |
| Work Temperatur | -25°C +60°C |
| Storage Temperature | -40°C +70°C |
| Relative Humidity | 55°C – RH 95% |
| Characteristics of auxiliary contacts in opening and closing state | |
| Opening and closing status | yes |
| Contact Type | Electronic Relay |
| Rated Voltage | 5V-230V AC/DC |
| Rated Current | 0.6 A(min) -3A (max) |
| Frequency | 50Hz |
| Use category | AC12 |
| Operation mode | NO\NC\COM Signal of Handle Position |
| Cable Connection | ≤ 2.5mm² |
| Rated Tightening Torque | 0.4Nm |
| Auto Reclose Function | |
| Auto recloser | √ |
| Reclose Stops when Fault | √ |
| Signal of Reclosing | √ |
| Fault Signal Indicator | √ |
| Reclosing function on/off | √ |
| Auxiliary Contact for Remote Operation | √ |
| Internal Electrical Protection | √ |