Page Title: CJ-T2-AC 275V 20-40kA 1-4P Surge Protective Device SPD | C&J Electrical DIN Rail Arrester Page Description: C&J Electrical presents the CJ-T2-AC series Type 2 AC Surge Protective Device. 275V/385V options, In 20kA, Imax 40kA, response time ≤25ns. OEM/ODM branding and SKD shipment available. Contact us for selection support and samples.

Date: November 23, 2026

In low-voltage distribution systems, induced lightning surges and switching overvoltages are among the leading causes of damage to downstream electronic equipment. The CJ-T2-AC 275V 20-40kA Power Surge Protective Device from C&J Electrical is engineered for intermediate and terminal protection between distribution boards and sensitive loads. Its pluggable module design and availability in 1P through 4P configurations make it adaptable to both single-phase and three-phase supply arrangements.

1 Key Technical Parameters at a Glance

From a procurement and selection standpoint, the CJ-T2-AC offers parameters that translate directly into engineering decisions. The table below summarizes the key technical data published on the product page for quick comparison by engineers and buyers.

Parameter Specification
Model CJ-T2-AC
Rated voltage (max. continuous AC voltage Uc) 275V or 385V
Nominal discharge current In (8/20μs) 20kA
Maximum discharge current Imax 40kA
Voltage protection level Up ≤1.5kV
Response time tA ≤25ns
Max. backup fuse 125A gL/gG
Operating temperature range Tu -40°C to +80°C
Cross-sectional area 1.5mm²–25mm² solid / 35mm² flexible
Mounting 35mm DIN rail
Enclosure material Purple (module) / light gray (base) thermoplastic, UL94-V0
Module width 1 mod
Remote signalling contact type Switching contact
Switching capacity AC 250V/0.5A
Switching capacity DC 250V/0.1A; 125V/0.2A; 75V/0.5A
Cross-sectional area for remote signalling Max. 1.5mm² solid/flexible
Weight 376g

The maximum continuous operating voltage (Uc) is available in 275V and 385V versions, covering common 220V/380V distribution scenarios. The nominal discharge current (In) is 20kA (8/20μs), maximum discharge current (Imax) reaches 40kA, voltage protection level (Up) is ≤1.5kV, and response time is ≤25ns. When a lightning transient or grid disturbance occurs, the SPD clamps the residual voltage to a level the downstream equipment can tolerate. For retrofit projects where panel space is limited, the single-module width and 35mm DIN rail mounting simplify installation.

2 Pole Configurations and System Matching

The product is offered in 1P through 4P configurations. The table below maps common distribution systems to recommended pole counts for selection reference.

Pole configuration Typical applicable system Common installation point
1P Single-phase two-wire (L-N) Terminal distribution board, equipment inlet
2P Single-phase two-wire with N protection Residential incoming panel, AC input of a Portable Power Station
3P Three-phase three-wire Industrial control cabinets, light commercial floor distribution
4P Three-phase four-wire (L1/L2/L3/N) Main distribution boards, PV grid-tie AC side

For three-phase four-wire systems, the 4P configuration protects all three phases and the neutral conductor simultaneously, avoiding equipment damage caused by neutral potential shift. In grid-tied PV scenarios, a 4P configuration on the AC side paired with a DC Surge Protection Device on the DC side establishes a coordinated AC/DC protection scheme.

3 Coordinated Selection with MCB Products

Our company also offers MCB products, which can be combined with the SPD for a coordinated distribution protection package. The table below outlines typical SPD–MCB pairings for procurement reference.

Protection stage Recommended product Function
Incoming overcurrent protection Miniature Circuit Breaker (6-63A, 6kA/10kA) Backup overcurrent protection for the SPD branch
Surge protection CJ-T2-AC (In 20kA / Imax 40kA) Clamps transient overvoltages, protects downstream loads
Residual current protection Rcbo Residual Circuit Breaker / Rccb Residual Current Circuit Breaker Earth fault and personnel shock protection
Smart monitoring (optional) Intelligent Circuit Breaker / Wifi Circuit Breaker Remote monitoring of circuit status and SPD signalling

4 Test Standards and Safety Construction

High safety performance is reflected in several construction details. Dual thermal disconnection devices provide reliable circuit isolation if the varistor degrades due to aging or sustained overvoltage, reducing fire risk. A status indicator window remains green under normal conditions and turns red upon failure, allowing maintenance personnel to assess module health without tools. A remote signalling contact is also provided for uploading failure status to monitoring systems, enabling preventive maintenance.

Test standards IEC 61643-1;
Thermal disconnection Dual thermal disconnection devices
Status indication Green normal / red failure
Remote signalling Switching contact, supports remote signal upload
Flame retardant rating PA6-V0
Environmental range -40°C to +80°C

5 Application Scenario Matching

Wide application suitability is another practical advantage. The table below organizes typical configurations by scenario to help buyers assess fit for their projects.

Application scenario Recommended configuration Supporting notes
Residential incoming panel protection 2P, 275V Installed alongside Miniature Circuit Breaker and Rcbo
Light commercial floor distribution 4P, 385V Coordinated with Mccb Circuit Breaker for graded protection
Industrial control cabinet secondary protection 3P/4P, 385V Protects PLCs, instruments and precision loads
PV grid-tie AC side 4P, 385V Pair with DC Surge Protection Device on DC side
Outdoor temporary power / storage equipment 2P, 275V Fits AC input of a Portable Power Station

In PV and energy storage scenarios, the AC input of a Power station Solar Panel setup or a Portable Power Station Generator also requires reliable surge protection. The CJ-T2-AC can serve as the incoming protective device for such equipment, used in conjunction with a Pure Sine Wave Inverter output stage to reduce equipment failure rates caused by grid fluctuations. For projects requiring remote monitoring, the SPD’s signalling contact can be integrated alongside Intelligent Circuit Breakers or Wifi Circuit Breakers into an operations platform.

6 Supply and Customization Services

On the supply side, C&J Electrical supports OEM/ODM brand customization services, with options to adjust product markings, packaging, and technical documentation to your requirements. Multiple specifications are available, including 385V versions and pole configurations from 1P to 4P. For customers with local assembly operations, we also support SKD (Semi-Knocked Down) shipment to help reduce logistics costs and import duties. If you have any questions or needs, please feel free to contact us. The C&J Electrical technical team can assist with SPD selection calculations, configuration recommendations, sample testing, and bulk supply arrangements.

About C&J Electrical

Zhejiang C&J Electrical Co., Ltd. focuses on the development and manufacturing of low-voltage electrical products, including surge protective devices, miniature circuit breakers, moulded case circuit breakers, and distribution accessories. We are committed to providing flexible customization services and dependable delivery support to customers worldwide.

Alt Text Recommendations:

  • Product image: “CJ-T2-AC 275V 20-40kA Surge Protective Device SPD DIN rail module by C&J Electrical”
  • Application image: “CJ-T2-AC SPD installed in distribution board with MCB for coordinated surge and overcurrent protection”
  • Table image: “CJ-T2-AC SPD technical parameters and pole configuration comparison by C&J Electrical”

Post time: Nov-24-2026