| Model | CJMM6E-160 | CJMM6E-250 | CJMM6E-400 | CJMM6E-630 | |||||||
| Frame current In | 32A(12~32A adjustable) 100A(40~100A adjustable) 160A(63~160A adjustable) |
250A(100A-250A adjustable) |
400A(160A-400A adjustable) (200A-400A adjustable) |
630A(250A-630A adjustable) (400A-630A adjustable) |
|||||||
| Short circuit breaking capacity code | S | M | H | S | M | H | M | H | M | H | |
| Number of poles | 3P/4P | ||||||||||
| Rated working voltage Ue (V), AC | AC400V/690V | ||||||||||
| Rated insulation voltage Ui (V) | 1000V | ||||||||||
| Rated impulse withstand voltage Uimp (kV) | 8kV | ||||||||||
| Rated service short-circuit breaking capacity Ics (%Icu) | AC 400V | 18kA | 35kA | 65kA | 18kA | 35kA | 65kA | 35kA | 70kA | 35kA | 70kA |
| AC 690V | 4kA | 8kA | 8kA | 8kA | 8kA | 8kA | 8kA | 8kA | 8kA | 8kA | |
| Rated ultimate short-circuit breaking capacity Icu (kA) | AC 400V | 25kA | 50kA | 65kA | 25kA | 50kA | 65kA | 50kA | 70kA | 50kA | 70kA |
| AC 690V | 8kA | 8kA | 8kA | 4kA | 8kA | 8kA | 8kA | 8kA | 8kA | 8kA | |
| Rated short-term withstand current Icw(kA) |
- | 10kA/1s | |||||||||
| Applicable frequency | 50/60Hz | ||||||||||
| Selective category | Class A | Class B | |||||||||
| Overcurrent release type | Electronic type | ||||||||||
| CJMM6 outline dimension(mm)Width (W)*Length |
Frame current | CJMM6E-160 | CJMM6E-250 | CJMM6E-400 | CJMM6E-630 | ||||||
| Number of poles | 3P | 4P | 3P | 4P | 3P | 4P | 3P | 4P | |||
| Width | 90 | 120 | 105 | 140 | 140 | 184 | 140 | 184 | |||
| Length | 155 | 155 | 165 | 165 | 257 | 257 | 257 | 257 | |||
| Height/face cover | 68/82 | 68/82 | 68/88 | 68/88 | 103 | 103 | 103 | 103 | |||
| Height/handle | 94/108 | 94/108 | 96/116 | 96/116 | 152 | 152 | 152 | 152 | |||
| Model | CJMM6E-800 | CJMM6E-1250 | CJMM6E-2000 | ||||
| Frame current In | 630A(400A-630A adjustable) 800A(500A-800A adjustable) |
1000A(630A-1000A adjustable) 1250A(850A-1250A adjustable) |
1250A(500A-1250A adjustable) 1600A(630A-1600A adjustable) 2000A(800A-2000A adjustable) |
||||
| Short circuit breaking capacity code | M | H | M | H | M | H | |
| Number of poles | 3P/4P | ||||||
| Rated working voltage Ue (V), AC | AC400V/690V | ||||||
| Rated insulation voltage Ui (V) | 1000V | ||||||
| Rated impulse withstand voltage Uimp (kV) | 8kV | ||||||
| Rated service short-circuit breaking capacity Ics (%Icu) | AC 400V | 50kA | 50kA | 50kA | 50kA | 50kA | 85kA |
| AC 690V | 10kA | 10kA | 10kA | 10kA | 20kA | 20kA | |
| Rated ultimate short-circuit breaking capacity Icu (kA) | AC 400V | 65kA | 65kA | 65kA | 65kA | 50kA | 100kA |
| AC 690V | 20kA | 20kA | 20kA | 20kA | 20kA | 20kA | |
| Rated short-term withstand current Icw(kA) |
20kA/1s | ||||||
| Applicable frequency | 50/60Hz | ||||||
| Selective category | Class B | ||||||
| Overcurrent release type | Electronic type | ||||||
| CJMM6 outline dimension(mm)Width (W)*Length |
Frame current | CJMM6E-800 | CJMM6E-1250 | CJMM6E-2000 | |||
| Number of poles | 3P | 4P | 3P | 4P | 3P | 4P | |
| Width | 210 | 280 | 210 | 280 | 210 | 340 | |
| Length | 275.5 | 275.5 | 275.5 | 275.5 | 340 | 280 | |
| Height/face cover | 103 | 103 | 103 | 103 | 141 | 141 | |
| Height/handle | 152 | 152 | 152 | 152 | 244 | 244 | |