Short Description:

  • The CJMM9 series circuit breakers are developed by our company to meet the demands of domestic and international markets. With a maximum rated insulation voltage of 1000V (690V for 125 frame size), these breakers are suitable for AC 50Hz, a rated operating voltage of 400V, and a rated operating current up to 1600A. They are used to distribute electrical power and protect circuits and power equipment from damage caused by overloads, short circuits, undervoltage, and other faults. They can also serve as infrequent starters for motors and provide overload, short-circuit, and undervoltage protection.
  • Classified by rated ultimate short-circuit breaking capacity into M-type and H-type.
  • Can be installed vertically (upright mounting) or horizontally (sideways mounting).
  • Complies with IEC 60947-2 and GB/T 14048.2 standards.

Product Detail

Product Tags

Working And Installation Conditions

  • Normal operating altitude below 2000m (above 2000m requires derating and appropriate parameter adjustments);
  • Normal ambient temperature not exceeding +40°C and not below -5°C (above +40°C or below -5°C requires derating and appropriate parameter adjustments);
  • Installation category III for the main circuit of the circuit breaker; installation category II for all auxiliary and control circuits;
  • Relative humidity not exceeding 50% at maximum temperature of +40°C. Higher relative humidity is permissible at lower temperatures. Special measures must be taken to prevent condensation caused by temperature fluctuations;
  • Pollution degree 3; protection rating IP30;
  • Installation in non-explosive environments free from gases or conductive dust capable of corroding metals or damaging insulation;
  • Installation in locations protected from rain and snow.

CJMM9 MCCB moulded case circuit breaker

Technical Data

Model CJMM9-125M CJMM9-160M CJMM9-160H CJMM9-250M CJMM9-250H
Shell Frame Class I mn(A) 125 160 250
Number of Poles 1, 2, 3, 4 3, 4
Rated Current In(A) 32, 40, 50, 63, 80, 100, 125 125, 140, 160 160, 180, 200, 225, 250
Rated Operating Voltage Ue(V) 230 (1P, 2P), 400 (3P, 4P)
Rated Insulation Voltage Ui(V) 690 800
Rated Impulse Withstand Voltage Uimp(kV) 6 8
Rated Ultimate Short-Circuit Breaking Capacity Icu(kA) 22 25 50 35 50
Rated Short-Circuit Breaking Capacity Ics(kA) 15 18 35 22 35
Usage Category A
Operating Cycle Count Powered 1500 1000 1000
Non-powered 8500 7000 7000
Trip Unit Type Thermal Trip Yes
Magnetic Trip Yes
Thermal-Magnetic Trip Yes
Installation Wiring Method Front panel wiring Yes
Rear Panel Wiring Yes
Plug-in wiring No Yes
Internal Accessories Auxiliary contacts Yes (1P models only)
Alarm contact Yes (1P only)
Shunt Trip or Undervoltage Trip Available for 3P and 4P (not available for 1P and 2P)
External Accessories Electromechanical operating device Available for 3P and 4P (not available for 1P and 2P)
Manual operation Available for 3P and 4P (not available for 1P and 2P)

 

Model CJMM9-400M CJMM9-400H CJMM9-630M CJMM9-630H
Frame Rating I mn(A) 400 630
Number of Poles 3, 4
Rated Current In(A) 250, 315, 350, 400 400, 500, 630
Rated Operating Voltage Ue(V) 400
Rated Insulation Voltage Ui(V) 1000
Rated Impulse Withstand Voltage Uimp(kV) 12
Rated Ultimate Short-Circuit Breaking Capacity Icu(kA) 50 65 50 65
Rated operating short-circuit breaking capacity Ics(kA) 35 50 35 50
Number of operating cycles Power-on 1000 1000
Non-powered 4000 4000
Trip device type Thermal trip Yes
Single magnetic trip Yes
Thermal-magnetic trip Yes
Installation Wiring Method Front panel wiring Yes
Rear Panel Wiring Yes
Plug-in wiring Yes
Internal accessories Auxiliary contacts Yes
Alarm contact Yes
Shunt Trip or Yes
Undervoltage Trip Unit
External Accessories Electric operating device Available
Manual Yes

 

Model CJMM9-800M CJMM9-800H CJMM9-1600M CJMM9-1600H
Frame Rating I mn(A) 800 1600
Number of Poles 3, 4
Rated Current In(A) 630, 700, 800 800, 1000, 1250, 1600
Rated Operating Voltage Ue(V) 400
Rated Insulation Voltage Ui(V) 1000
Rated Impulse Withstand Voltage Uimp(kV) 12
Rated Ultimate Short-Circuit Breaking Capacity Icu(kA) 50 65 50 75
Rated operating short-circuit breaking capacity Ics(kA) 35 50 35 66
Number of operating cycles Power-on 500 500
Non-powered 2500 2500
Trip Device Type Thermal trip Yes
Single magnetic trip Yes
Thermal-magnetic trip Yes
Installation Wiring Method Front panel wiring Yes
Rear Panel Wiring Yes
Plug-in Wiring Yes None
Internal Accessories Auxiliary contacts Yes
Alarm contact None Yes
Shunt Trip Unit Yes
Undervoltage Trip None None
External Accessories Electric operating device Yes
Manual Yes