We goal to understand excellent disfigurement from the manufacturing and supply the high support to domestic and abroad clients wholeheartedly for Auto Recloser Elcb , Ge Molded Case Circuit Breaker , Ac Dc Mcb , We welcome you to join us in this path of creating a prosperous and efficient business together.
CE Certification Rcbo Current Ratings Exporter Residual Current Circuit Breaker with Overcurrent Protection CJRO2-40 – C&J Detail:
Construction and Feature
- Provides protection against earth fault/leakage current, short-circuit, overload, and function of isolation.
- Contact position indication
- Provides protection against indirect contact by human body
- Provides complementary protection against direct contact by human body.
- Effectively protects electric equipment against insulating failure
- Equipped with switched neutral and phase pole
- Provides protection against over-voltage
- Provides comprehensive protection to household and commercial distribution systems.
- S2 Shunt Tripper
- U2+O2 Over-voltage and under-voltage tripper
Technical Data
| Standard |
IEC61009-1/EN61009-1 |
| Type |
Electronic type |
| Residual current characteristics |
AC |
| Pole No |
1P+N |
| Tripping curve |
B, C, D |
| Rated short-circuit capacity |
6kA |
| Rated current (A) |
6A, 10A, 16A, 20A, 25A, 32A |
| Rated voltage |
230V AC |
| Rated frequency |
50/60Hz |
| Rated residual operating current(mA) |
0.03, 0.1, 0.3 |
| Tripping duration |
instantaneous≤0.1s |
| Electro-mechanical endurance |
4000 cycles |
| Connection terminal |
pillar terminal with clamp |
| Terminal Connection Height |
H1=16mm H2=21mm |
| Over-voltage tripping |
280V±5% |
| Connection capacity |
Flexible conductor 10mm² |
| Rigid conductor 16mm² |
| Installation |
On symmetrical DIN rail 35.5mm |
| Panel mounting |
Overload Current Protection Characteristics
| Test procedure |
Type |
Test Current |
Initial State |
Tripping or Non-tripping Time Limit |
Expected Result |
Remark |
| a |
B,C,D |
1.13In |
cold |
t≥1h |
no tripping |
|
| b |
B,C,D |
1.45In |
after test a |
t<1h |
tripping |
Current in the 5s in th increase of stability |
| c |
B,C,D |
2.55In |
cold |
1s<t<60s |
tripping |
|
| d |
B |
3In |
cold |
t≤0.1s |
no tripping |
Turn on the auxiliary switch to close the current |
| C |
5In |
| D |
10In |
| e |
B |
5In |
cold |
t<0.1s |
tripping |
Turn on the auxiliary switch to close the current |
| C |
10In |
| D |
20In |
| The terminology “cold state” refes to that no load is carried before testing at the reference setting temperature. |
Residual Current Action Breaking Time
| Residual Current Action Breaking Time |
| type |
In/A |
I△n/A |
Residual Current (I△) Is Corresponding To The Following Breaking Time (S) |
| I△n |
2 I△n |
5 I△n |
5A,10A,20A,50A,100A,200A,500A |
I△t |
|
general
type |
any
value |
any
value |
0.3 |
0.15 |
0.04 |
0.04 |
0.04 |
Max Break-time |
A Type Of Trip Current Range
| Lagangle(A) |
A Tripping Current(A) |
| Lower Limit |
Upper Limit |
| 0° |
0.35 I△n |
0.14 I△n |
| 90° |
0.25 I△n |
| 135° |
0.11 I△n |
Product detail pictures:
Related Product Guide:
We also offer product sourcing and flight consolidation services. We've got our personal factory and sourcing office. We can easily present you with almost every style of merchandise linked to our merchandise range for CE Certification Rcbo Current Ratings Exporter Residual Current Circuit Breaker with Overcurrent Protection CJRO2-40 – C&J , The product will supply to all over the world, such as: Borussia Dortmund, Canada, Marseille, Our solutions are widely recognized and trusted by users and can meet continuously changing of economic and social needs. We welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!
This is a reputable company, they have a high level of business management, good quality product and service, every cooperation is assured and delighted!
By Nicole from South Korea - 2018.09.19 18:37
The company can think what our think, the urgency of urgency to act in the interests of our position, can be said this is a responsible company, we had a happy cooperation!
By Julia from Turin - 2018.02.12 14:52