CE Certification Dc Rcbo Exporter Residual Current Circuit Breaker with Overcurrent Protection CJRO2-40 – C&J Detail:
Construction and Feature
- Provides protection against earth fault/leakage current, short-circuit, overload, and function of isolation.
- Contact position indication
- Provides protection against indirect contact by human body
- Provides complementary protection against direct contact by human body.
- Effectively protects electric equipment against insulating failure
- Equipped with switched neutral and phase pole
- Provides protection against over-voltage
- Provides comprehensive protection to household and commercial distribution systems.
- S2 Shunt Tripper
- U2+O2 Over-voltage and under-voltage tripper
Technical Data
| Standard |
IEC61009-1/EN61009-1 |
| Type |
Electronic type |
| Residual current characteristics |
AC |
| Pole No |
1P+N |
| Tripping curve |
B, C, D |
| Rated short-circuit capacity |
6kA |
| Rated current (A) |
6A, 10A, 16A, 20A, 25A, 32A |
| Rated voltage |
230V AC |
| Rated frequency |
50/60Hz |
| Rated residual operating current(mA) |
0.03, 0.1, 0.3 |
| Tripping duration |
instantaneous≤0.1s |
| Electro-mechanical endurance |
4000 cycles |
| Connection terminal |
pillar terminal with clamp |
| Terminal Connection Height |
H1=16mm H2=21mm |
| Over-voltage tripping |
280V±5% |
| Connection capacity |
Flexible conductor 10mm² |
| Rigid conductor 16mm² |
| Installation |
On symmetrical DIN rail 35.5mm |
| Panel mounting |
Overload Current Protection Characteristics
| Test procedure |
Type |
Test Current |
Initial State |
Tripping or Non-tripping Time Limit |
Expected Result |
Remark |
| a |
B,C,D |
1.13In |
cold |
t≥1h |
no tripping |
|
| b |
B,C,D |
1.45In |
after test a |
t<1h |
tripping |
Current in the 5s in th increase of stability |
| c |
B,C,D |
2.55In |
cold |
1s<t<60s |
tripping |
|
| d |
B |
3In |
cold |
t≤0.1s |
no tripping |
Turn on the auxiliary switch to close the current |
| C |
5In |
| D |
10In |
| e |
B |
5In |
cold |
t<0.1s |
tripping |
Turn on the auxiliary switch to close the current |
| C |
10In |
| D |
20In |
| The terminology “cold state” refes to that no load is carried before testing at the reference setting temperature. |
Residual Current Action Breaking Time
| Residual Current Action Breaking Time |
| type |
In/A |
I△n/A |
Residual Current (I△) Is Corresponding To The Following Breaking Time (S) |
| I△n |
2 I△n |
5 I△n |
5A,10A,20A,50A,100A,200A,500A |
I△t |
|
general
type |
any
value |
any
value |
0.3 |
0.15 |
0.04 |
0.04 |
0.04 |
Max Break-time |
A Type Of Trip Current Range
| Lagangle(A) |
A Tripping Current(A) |
| Lower Limit |
Upper Limit |
| 0° |
0.35 I△n |
0.14 I△n |
| 90° |
0.25 I△n |
| 135° |
0.11 I△n |
Product detail pictures:
Related Product Guide:
The customer satisfaction is our primary goal. We uphold a consistent level of professionalism, quality, credibility and service for CE Certification Dc Rcbo Exporter Residual Current Circuit Breaker with Overcurrent Protection CJRO2-40 – C&J , The product will supply to all over the world, such as: Hyderabad, Bangalore, Indonesia, We win many reliable customers by rich experience, advanced equipments, skilled teams, strict quality control and good service. We can guarantee all our products. Customers' benefit and satisfaction are always our big goal. Please contact us. Give us a chance, give you a surprise.
The company's products can meet our diverse needs, and the price is cheap, the most important is that the quality is also very nice.
By Eleanore from UAE - 2017.02.18 15:54
In our cooperated wholesalers, this company has the good quality and reasonable price, they are our first choice.
By Eve from Southampton - 2018.09.29 17:23